MATSUZAWA DIGITAL VICKERS HARDNESS TESTER
- AUTO TURRET
Auto turret allows one-touch operation for troublesome lens-indenter-lens changeover required in the measurement.
- LIQUID CRYSTAL DISPLAY TOUCH PANEL
Large LCD touch panel with a clear display and back light can perform various data processing and other function.
- REPUTED LOADING MECHANISM
Loading mechanism with no fluctiation, "capable to hit aimed portion", is highly evaluated.
- HK KNOOP HARDNESS
Knoop hardness calculating functions can be changed over with a one touch panel operation. (HK diamond indenter is optional)
- TWO OBJECT LENSES CAN BE MOUNTED SIMULTANEOUSLY
In addition to the normal measuring lens (X10 or X20), one more lens of different magnification can be mounted regularly. (Additional lens is optional.)
- HIGH RIGDITY BODY ADOPTED
Newly designed VMT-7(7S) can perform high accuracy, measurements with its specially rigidity enhanced body.
- APPLICABLE TO CE (concurrent engineering)
Safety design applicable to EU low voltage command, EMC command and machine command. Metal fittings are attached as standard to prevent overturning by vibrations caused by earthquake, etc.
SPECIFICATIONS | ||||
ITEM | CONTENTS | |||
MODEL | VMT-X1 | VMT-X3 | VMT-X7 | |
Test load | _ |
9.807 19.61 29.42 49.03 98.07 196.1 294.2 490.3 N 1 2 3 5 10 20 30 50 kgf |
||
S |
2.942 4.903 9.807 29.42 49.03 98.07 196.1 294.2 N 0.3 0.5 1 3 5 10 20 30 kgf |
|||
Loading mechanism | Automatic loading and releasing | |||
Turret | Manual | Automatic | ||
Load applying speed | 8.5 µm/sec | |||
Dwell time | 5~40 sec | 5~99 sec | ||
Magnification of microscope | X100 (Object lens X 10, eyepiece X 10) | |||
X 200 For 'S' Model (Object lens X 20, eyepiece X 10) | ||||
Max measuring length | 100X :999.9 µm (200 x : 600.0 µm) | |||
Min. measuring unit | 0.1 µm | 0.1 µm (200X~1000X), 0.02µm (100X) | ||
Max. specimen height | 260 mm | |||
Max. specimen depth | 160mm | |||
LCD touch-panel | Data Memory | - | Max 999 test data | |
Hardness conversion | - | Possible in compliance with ASTM(E-140),JIS. | ||
OK/NG Criteria | - | Upper and lower limits setting, and HI/OK/LOW display. | ||
Data editing | - | Data output & display. Max value, Min value, dispersion (R), mean value, standard deviation. | ||
RS-232C Communication Lin | - |
Baud rate: 1200/2400/4800/9600 bps selectable (RS-232C) Error detection, Parity even/ Parity none selectable (RS-232C) |
||
Data Output | - |
1) Centronics (standard) 2) RS232C or serial output selectable (Factory Setting) |
||
Accuracy | Conform to JIS B7725 and ASTM E-92 | |||
Photographic device (optional) | Possible to mount at anytime | |||
Dimensions of tester | Main body only: W220 X D580 X H770mm | |||
Weight | 52Kg | |||
Power Supply |
AC 100V 50/60HZ (in Japan) For overseas. Possible to change up to AC 240V |